0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Assessment of the Seismic Response of Isolated Bridges under extra- stroke displacement demands

 Assessment of the Seismic Response of Isolated Bridges under extra- stroke displacement demands
Auteur(s): ,
Présenté pendant IABSE Symposium: Towards a Resilient Built Environment Risk and Asset Management, Guimarães, Portugal, 27-29 March 2019, publié dans , pp. 251-257
DOI: 10.2749/guimaraes.2019.0251
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.79 MB

Seismic isolation techniques for bridge structures have been more and more improved in last years, thanks to results of both numerical and experimental investigations on full-scale devices. In addi...
Lire plus

Détails bibliographiques

Auteur(s): (University of Pavia, EUCENTRE, Pavia, Italy)
(University of Pavia, Pavia, Italy)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Towards a Resilient Built Environment Risk and Asset Management, Guimarães, Portugal, 27-29 March 2019
Publié dans:
Page(s): 251-257 Nombre total de pages (du PDF): 7
Page(s): 251-257
Nombre total de pages (du PDF): 7
DOI: 10.2749/guimaraes.2019.0251
Abstrait:

Seismic isolation techniques for bridge structures have been more and more improved in last years, thanks to results of both numerical and experimental investigations on full-scale devices. In addition, significant advances on testing techniques have led to extremely realistic responses of an isolated bridge. Particularly, hybrid tests allow to consider a numerical model of the overall structure, together with an experimental contribution, represented by the real force of a full-scale isolation device. Generally, the response of an isolated bridge structure is strongly affected by the valley topography: consequently high piers may not need isolation devices, since they are enough flexible to accommodate the design displacement in the elastic range. On the other hand, at those locations no hysteretic damping is provided and higher displacements can be achieved, in comparison to the design value.

In this work the seismic response of an isolated bridge case study structure has been investigated, through non linear time history analyses, by accounting for the effective contribution of both isolators and elastic response of piers. Moreover, the actual hysteretic behaviour of all devices has been properly modelled, also for displacements higher than the design value, so in the extra- stroke range. Results have been compared to the ordinary response, which accounts for no difference between forces under displacements lower rather than higher than the target value, in order to highlight main consequences of such a behaviour on the overall response parameters.