Seismic Assessment of a Single-Column Elevated Station Structure

Auteur(s):


Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 7, v. 13
Page(s): 1827
DOI: 10.3390/buildings13071827
Abstrait:

Single-column elevated station structures are irregular structures with long-span cantilever beams and individual pier columns in the transverse section. The uneven mass and stiffness in the horizontal and vertical planes necessitate research on the seismic performance of these structures. This study performed a nonlinear response-history analysis (NRHA) of a single-column elevated station structure using the finite element program MSC.MARC and analysed its seismic performance under different seismic intensities. The stress states of the primary components were evaluated, and the effect of vertical earthquake motion on the seismic performance of the structure was considered. The torsional behavior caused by the uneven mass and stiffness in both horizontal and vertical directions should be considered, and energy dissipation measures should be taken to reduce the internal force and deformation of the bottom-pier columns and second-floor columns in the process of designation to improve the seismic performance of the structure. A bidirectional pushover analysis (BPA) was applied. The load amplification factor was adjusted to optimize the BPA results. The results of the modified BPA were similar to those of the NRHA, indicating the computational reliability of the modified BPA. The modified BPA method was accurate, applicative, and efficient. The BPA can improve computational efficiency compared to NRHA and can be widely applied in the structural design process for practical engineering applications.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10737177
  • Publié(e) le:
    03.09.2023
  • Modifié(e) le:
    14.09.2023
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine