Effect of Interior Space and Window Geometry on Daylighting Performance for Terrace Classrooms of Universities in Severe Cold Regions: A Case Study of Shenyang, China

Auteur(s):
ORCID




Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 3, v. 13
Page(s): 603
DOI: 10.3390/buildings13030603
Abstrait:

Good daylighting performance positively affects students’ physical and mental health, learning efficiency, and the building’s energy-saving capability. Due to the terrace classroom having ample space, large capacity, the ability to avoid obstructing sight, and the ability to meet various use needs, it is the most important place in university buildings. However, research on the daylighting performance of university terrace classrooms is limited, leading to a lack of quantitative guidance in early design stages. This study aims to explore the effects of interior space and window geometry of terrace classrooms in universities in severe cold regions on daylighting performance. This research took Shenyang as an example; spatial daylight autonomy (sDA300,50%) and useful daylight illuminance (UDI100–2000) were selected as daylighting performance evaluation indices. Based on the Grasshopper parametric platform, the simulation was carried out using Ladybug and Honeybee plugins. Correlation and regression analyses revealed the relationship between interior space and window geometry parameters and the evaluation indices. The results showed the following: window-to-floor ratio (WFR), classroom height (Htc), window height (Hw), window-to-wall ratio (WWR), classroom width (Wtc), and window width (Ww) have positive effects on improving the daylight sufficiency of the terrace classrooms facing each orientation, and the degree of the effect decreases in order. To ensure the overall daylighting performance, the Wtc can be maximized. The width of walls between windows for south-facing and west-facing classrooms should be 0.9 m. The WWR and WFR for south-facing classrooms should be 0.3–0.5 and 0.11–0.14, respectively. The WWR and WFR for north-facing classrooms should be 0.6–0.7 and 0.14–0.20, respectively. Prediction models are established for the sDA300,50% and UDI100–2000 of the terrace classrooms facing each orientation.

Copyright: © 2023 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10711972
  • Publié(e) le:
    21.03.2023
  • Modifié(e) le:
    10.05.2023
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine