0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Analysis of a heavy goods vehicle fire in wind conditions and its impact on structural performance of a cable-stayed bridge

 Analysis of a heavy goods vehicle fire in wind conditions and its impact on structural performance of a cable-stayed bridge
Auteur(s): , ,
Présenté pendant IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015, publié dans , pp. 921-928
DOI: 10.2749/222137815818358097
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.08 MB

With growing concern over the fire risk of bridges, an analysis of temperature fields of heavy goods vehicle (HGV) and the impacts on bridge structure was conducted, by taking a cable-stayed bridge...
Lire plus

Détails bibliographiques

Auteur(s): (Tongji University, Shanghai, China)
(Tongji University, Shanghai, CHINA)
(Tongji University, Shanghai, China)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015
Publié dans:
Page(s): 921-928 Nombre total de pages (du PDF): 8
Page(s): 921-928
Nombre total de pages (du PDF): 8
Année: 2015
DOI: 10.2749/222137815818358097
Abstrait:

With growing concern over the fire risk of bridges, an analysis of temperature fields of heavy goods vehicle (HGV) and the impacts on bridge structure was conducted, by taking a cable-stayed bridge as a research object. With the test data of HGV fire in the Runehamar tunnel in Norway, the HGV fire model was obtained with numerical simulation. Using this model, the flame temperatures of HGV fire on the bridge deck were acquired at wind velocities of 0 m/s, 2.5 m/s and 5 m/s respectively. Considering the heat transfer characteristics of fire, the temperatures of stay cables were also achieved, and then the failures of stay cables were studied. After that, the safety assessment of bridge was conducted. The results show that the wind could reduce the damage of stay cables caused by fire. And the HGV fire has limited influence on the overall safety performance of bridge, but will pose a serious threat to the reliability and durability of bridge. So it’s necessary to take effective measures to reduce the loss caused by fire.

Mots-clé:
vent Pont à haubans